Pickerington

Local Reviews
for Pickerington, OH


Noah B.

Noah B.

Performed indoor air quality test in a customer's home. Air quality tested good at this time.

Near Wagonwood Dr NW, Pickerington, OH 43147
Pickerington, OH - Performed indoor air quality test in a customer's home. Air quality tested good at this time.
Noah B.

Noah B.

Thermostat for Carrier furnace kept calling to replace filter. Rebooted the thermostat, confirmed the wiring, performed air flow verification test with clean filter. Fault not present at this time.

Near Teal Ln, Pickerington, OH 43147
Pickerington, OH - Thermostat for Carrier furnace kept calling to replace filter. Rebooted the thermostat, confirmed the wiring, performed air flow verification test with clean filter. Fault not present at this time.
Noah B.

Noah B.

Performed tuneup and safety inspection on Rheem furnace. The system is operating under manufacturer's guidelines. It is ready to heat this winter season.

Near Raintree Ave, Pickerington, OH 43147
Pickerington, OH - Performed tuneup and safety inspection on Rheem furnace. The system is operating under manufacturer's guidelines. It is ready to heat this winter season.
Noah B.

Noah B.

Diagnosed Carrier furnace with thermostat that keeps flashing to replace filter. The thermostat filter indicator, (airflow resistance) alert was on. Found dirty filter, one week old filter, can’t see light through the filter much at all. Replaced filter, all good at this time.

Near Teal Ln, Pickerington, OH 43147
Pickerington, OH -      Diagnosed Carrier furnace with thermostat that keeps flashing to replace filter. The thermostat filter indicator, (airflow resistance) alert was on. Found dirty filter, one week old filter, can’t see light through the filter much at all. Replaced filter, all good at this time.
Noah B.

Noah B.

Performed indoor air quality test in customer's home to ensure a safe breathing environment and home comfort. This complimentary test found that the indoor air quality is good at this time.

Near N Crosset Hill Dr, Pickerington, OH 43147
Pickerington, OH - Performed indoor air quality test in customer's home to ensure a safe breathing environment and home comfort. This complimentary test found that the indoor air quality is good at this time.
Noah B.

Noah B.

Getting error codes on newly installed Carrier system. Cycled system and it over heated in minutes. Changed dip switch settings and ran in low stage. Return and temp rise are good at this time.

Near Kilger Ct, Pickerington, OH 43147
Pickerington, OH - Getting error codes on newly installed Carrier system. Cycled system and it over heated in minutes. Changed dip switch settings and ran in low stage. Return and temp rise are good at this time.
Noah B.

Noah B.

Diagnostic Performed Replaced Capacitor On Gas Furnace To Keep Furnace Running Efficiently For The Winter Season

Near Kilger Ct, Pickerington, OH 43147
Noah B.

Noah B.

Customer complained that Carrier furnace would turn on then shut off after 2 minutes. Upon arrival, found that the house was in the 50s and the thermostat was set to high 60s. Wrong size filter was installed and found water in the pressure switch lines. Blew out the water.Pulled and cleaned trap, and removed small lump of debris. The furnace is now working properly.

Near Ashford Ln NW, Pickerington, OH 43147
Pickerington, OH - Customer complained that Carrier furnace would turn on then shut off after 2 minutes. Upon arrival, found that the house was in the 50s and the thermostat was set to high 60s. Wrong size filter was installed and found water in the pressure switch lines. Blew out the water.Pulled and cleaned trap, and removed small lump of debris. The furnace is now working properly.
Noah B.

Noah B.

Carrier furnace was running but was not producing any heat. Checked outdoor ventilation and found no obstructions. There were a few bugs in the condensate trap and accumulated water in the exhaust pipe and inducer housing. Pulled, cleaned, drained and recycled. The system fired up and was producing heat. All checks good at this time.

Near Alvamar Ct, Pickerington, OH 43147
Pickerington, OH - Carrier furnace was running but was not producing any heat. Checked outdoor ventilation and found no obstructions. There were a few bugs in the condensate trap and accumulated water in the exhaust pipe and inducer housing. Pulled, cleaned, drained and recycled. The system fired up and was producing heat. All checks good at this time.
Noah B.

Noah B.

Customer concerned about excessive water noise from the humidifier. Found that the water pressure was very high. Gradually adjusted water flow for optimal usage to reduce splashing from high pressure water. Now the humidifier is not making noise , has no leaks, and pad is in good condition. Recommend replacing humidifier soon.

Near Ceresia Ct, Pickerington, OH 43147
Pickerington, OH - Customer concerned about excessive water noise from the humidifier. Found that the water pressure was very high. Gradually adjusted water flow for optimal usage to reduce splashing from high pressure water. Now the humidifier is not making noise , has no leaks, and pad is in good condition. Recommend replacing humidifier soon.